15~60MW COMBINED CYCLE STEAM TURBINE
Main Technical Data
Type
Output
(MW)
Speed
(r/min)
Direction of Rotation
Rated Steam Parameters
Maximum extraction
flow for
industrial
process
(t/h)
feed water
temperature
(℃)
Pressure
(Mpa.a)
Temperature
L15-3.43
14.35
3000
clockwise
viewed
downstream
3.43
440
10.7
50.2
L18-3.43-4
18
5.02
135.1
L25-3.43-3
25
435
10.6
104.3
L36-6.7
36.1
6.7
465
10.5
47.3
LZ60-5.6/0.56
60
5.6
527
8.08
73.1
type
Height of
operation
floor
(m)
Total weight
Of turbine
proper
(t)
Upper-half
weight
of turbine
rotor
External
dimension
( mm)
Central line height
(mm)
44
13.8
6.45
5290×3590×3530
750
72
19
6628×4890×3685
900
73.6
18.8
10.53
6627×4890×3685
85
23
12
7005×5040×3685
150
24
20.53
800
Rated Extraction Conditions
( Mpa.a)
Flow
0.56
255
33