点击察看大图
  MS9001E Gas Turbine Generating Set

  Detil:

    

MS9001E Gas Turbine Generating Set

It is a kind of packaged unit with a common base and four major compartments: control, accessory, gas turbine and generator. It can be arranged outdoor or indoor. The gas turbine control panel, generator control panel and protection panel, motor control center are arranged in the control compartment. Cabinets of generator neutral point and outgoing-line are set at both sides of generator. The unit has an enclosure with necessary ventilation, lighting and fire-fighting systems, Air conditioning is set for control compartment.

MS9001Egas Turbine

    MS9001E gas turbine consists mainly of air inlet system, compressor, combustor, turbine, exhaust system, accessory system and control system, etc. Air enters compressor through the inlet air filters and silencers. The compressed air then, gets into combustors and mixed with fuel, which is ejected by fuel nozzles in the combustors. The fuel and compressed air are burned to produce high-pressure and high-temperature gas, and then the gas expands in turbine to generate power. After expansion, it exhausts to atmosphere through exhaust system (or to HRSG)

Gas-Steam Combined Cycle

    Gas turbine can be operated both in simple cycle and in combined cycle. In the first, the expanded gas with higher temperature is exhausted to atmosphere directly, while in combined cycle, the exhausted gas will get into HRSG (Heat Recovery Steam Generator) to produce steam, then enters a steam turbine for generating power and/or cogeneration. Arrangements for combined cycle are S109E and S209E. S109E consists of one M9001E gas turbine, one HRSG and one steam turbine. S209E consists of two MS9001E, tow HRSG and one steam turbine.

    Gas-steam combined cycle has many advantages, mainly as follows:

1) It is clean power plant without ash and little pollution. Good environment can be got.

2) High thermal efficiency. The efficiency of S109E plant can be 50% above.

3) Less installation area

4) Less tap water. Usually, water flow is one of third for steam turbine power plant with same output.

5) Operation is flexible. Start or shutdown is fast. It can be used for base or peak load.

6) Short construction period and quick repayment

7) High automation and less staff

8) Fuel variability such as natural gas, distillate oil and heavy oil

9) Economic investment.

    In order to meet the different customers’ requirements on steam turbine generating sets in combined cycle plant, we have developed 60MW and 135MW steam turbine generators which 60MW steam turbine generator is used for S109E gas-steam combined cycle. These units could satisfy different customers with different requirements on combined cycle power plant or cogeneration power plant.

   It is a pedestal 3-phase synchronous generator. The insulation for both stator and rotor is F class. Exciter is brushless exciting and is equipped with a high accuracy AVR (Automatic Voltage Regulator).So that the power factor and voltage can be controlled, adjusted and protected.

 

 Parameter:

Gas Turbine Performance

    Main performance parameters under ISO condition(inlet temperature of compressor.15;Relative humidity: 60%; Atmospheric pressure:1.013bar), inlet air pressure loss;88.9mmH2O and exhaust air pressure loss:127mmH2O:

Model

PG9171E

Structure Type

Standard

Standard

Standard

DLN+Extraction Heating

Fuel

Natural Gas

Distillate Oil

Heavy Oil

Natural Gas

Output

126100 kW

123300 kW

115300 kW

125400 kW

Heat Rat(LHV)

10650 kJ/kWh

10730 kJ/kWh

10960 kJ/kWh

10700 kJ/kWh

Heat Cons(LHV)

1343×106 kJ/h

1328×106 kJ/h

1263.7×106 kJ/h

1340.8×106 kJ/h

Exhaust Temp

543

543

520

543

Exhaust Flow

1505×103kg/h

1509×103kg/h

1508.6×103kg/h

1504×103kg/h

Shaft Speed

3000r/min

3000r/min

3000r/min

3000r/min

 

Main Performance Parameters of Gas Turbine Generator

额定输出

135MW

Rated Output

135MW

额定转速

3000r/min

Rated Speed

3000r/min

频率

50Hz

Frequency

50Hz

功率因素

0.85

Power Factor

0.85

满载效率

98.2%

Eff. at Full Load

98.2%

转向(从原动机端看)

逆时针

Direction of Rotation

(Viewed from turbine end)

Anti-clockwise

短路比

0.51

Short Circuit Ratio

0.51

接线

Y

Connection

Y

保护型

封闭式

Protection

CACW